The file engine scanned its sources first and started watching them
after, so a change made between the two - after the scan had passed a
file, before the watcher began - waited for the next scan, five minutes
by default. And macOS reports file events through FSEvents, which
delivers nothing for a moment after a watcher is created: an EVERYTHING
run on a loaded Mac lost a log line appended right after the start
(tests/integration/continuousBackup.test.cjs, "the appended log line was
streamed by watching", 4 !== 5).
The watchers start first now; a change seen by the scan and a watcher
too is recorded once, as they share one queue. On macOS one catch-up
scan runs two seconds after the start. Not elsewhere: inotify is
watching when fs.watch returns, and a second full scan of a large store
would double the start-up cost.
A new test, on macOS and Linux, with a watcher that never reports:
watching starts before the first scan; on macOS the catch-up scan
records a change made right after the start; on Linux no second scan
runs. It fails on the code before this change.
Thanks to xet7 !